Chinese diesel heater error codes

What shape is yours? Follow the correct table of codes. Just like your vehicle, running out of diesel can require that your fuel lines are purged of air to remove any air block. This is normal and will clear in due course if left running. Unit will respond with E10 and fail to start.

If a no heater fault found is discovered by our engineer I. An area charge may also be applicable, depending on callout postcode area. We aim to appoint within 10 working days, however this may be extended during holiday periods. The additive can cause your heater to flame out and issue a no fuel E08 warning. The effect of this is additional sooting, causing an exhaust blockage. Service calls discovered with additives will be chargeable as it is not a heater fault. Colour controller.

Check leads and replace if necessary. Can be low voltage. Check lead to fuel pump, check connector is clicked in place. Check air intake is not restricted at rear of heater, check fan is not impeded. Plus any required replacement parts. Again can be low voltage. E08 lack of fuel may need to be restarted a number of times to refill fuel lines. After a few failed attempts the heater should ignite and clear errors.Log in or Sign up.

MIG Welding Forum. Messages: 6, Location: Leeds, West Yorkshire. KayosSep 13, Messages: 5, Location: Yorkshire. Do you use Facebook? There is a group, absolute gold mine of info.

chinese diesel heater error codes

I left though as my heater worked out of the box and didn't soot up. Are you sure its primed? Mine took 2 or 3 priming cycles to get all the air out of the fuel line. Might be an idea to pull the fuel line off the heater and point it into a jam jar to check the flow. Can you also measure the current draw before it shuts down? The glow plug should draw over 10 amps as it heats up. There is a Facebook page dedicated to these heaters which is really helpful for fixing issues.

Doesn't seem to have caused any issues. Messages: 4, Location: devon, uk. I doubt it would have damaged anything Check glow plug current draw if you can. Messages: 9, Location: westyorkshire. I would wait until you've got a good PSU. CobblerSep 13, Messages: 4, Location: Gloucestershire UK. Just worth remembering if running it from a power supply. Did you manage to measure the current draw and voltage on startup?

You must log in or sign up to reply here. Show Ignored Content. Your name or email address: Do you already have an account? No, create an account now.Warmda Fault and Error Codes.

Please find a downloadable pdf of error codes here: Warmda Fault and Error Codes. E01 Flame sensor open circuited Please connect the lead properly if it's loose. E02 Flame sensor short circuited Use multimeter to check if the flame sensor is short circuited or open circuited. Please repair or replace it if true.

Frequently Asked Questions - All FAQs

Use multimeter to check if the flame sensor is broken. Please replace it if true. E03 Flame temperature exceeds the maximum safe temperature Check if the air inlet, outlet and the exhaust pipe are blocked. Please clean up if true. E04 Flame temperature is lower than the minimum ignition temperature; ignition failure Check whether there is fuel inside the tank. If not, please refuel. Check whether the fuel pipe is blocked, and whether the connection is correct.

If not, please repair or replace it. Check whether the fuel is frozen. If true, please use fuel suitable for low-temperature environment. Check whether the exhaust pipe is blocked. If true, please clean it up. Please replace the controller E05 Air sensor open circuited Please check the plug of the air sensor.

E06 Air sensor short circuited Please contact the dealer or manufacturer. E07 Overhigh supply voltage Use multimeter to check the voltage of power. If it's lower than DC 20V, please charge the battery or use a new one; if it's higher than DC 30V, please use a new battery. E08 Over or low supply voltage Use multimeter to check the voltage of power. If it's lower than DC 10V, please charge the battery or use a new one; if it's higher than DC 15V, please use a new battery.

E09 Glow pin grounded Check if the glow pin is broken. If true, please replace it; use multimeter to check the resistance value between two leads of the glow pin. The value should be within Ohm. Please replace it if not. E11 Glow pin open circuited Please connect the lead properly if it's loose. E12 Fan motor open circuited Please connect the electric motor plug properly if it's loose.

E13 Fan motor short circuited Test electrically the electric motor to see if it operates properly. E14 Electromagnetic pump failure Please connect the lead properly if it's loose. E15 Electromagnetic pump failure Use multimeter to check the resistance value of fuel pump. It should be within Ohm. Please replace it if the value is out of range.

E16 Heater offline serial port error between the main board and the heater Please correct the serial connection. E17 Altitude sensor failure fail to read the altitude Please repair or replace the altitude sensor.

E18 Reserved E19 Boot failure of the heater Please check whether there is fuel in the fuel tank; check whether there is carbon in the air outlet. If true, please clean the carbon; Aging of glow pin. Use multimeter to check if the flame sensor is short circuited or open circuited. Check if the air inlet, outlet and the exhaust pipe are blocked.DHL or ParcelForce.

Your tracking number will be advised on dispatch both to your mobile number by txt and also your registered email address used on order. Please note that we cannot accept back for a refund any pressure vessel or any gas part that has been previously fitted, filled or used with gas due to the safety restrictions and courier and post office shipping guidelines for dangerous goods. You do not need to give us any reason for canceling your contract nor will you have to pay any penalty.

chinese diesel heater error codes

All GasIt orders are classed as Special Orders. Failing this authorisation, we cannot accept any returns of special order items. Once we receive your completed order we will contact you by telephone to arrange a suitable appointment for our mobile engineer to attend and fit your new heater. Fitting times are normally 10 - 20 days in advance, but this can be shorter, depending on volume of appointments.

We do our best to have your unit fitted at the earliest possible time. The actual heating unit can be installed either within the vehicle which is the normal or underslung additional cost for bracketingagain depending on your preference.

Whilst we will endeavour to fit in your preferred location, we cannot guarantee that this will be possible due to specific constraints on your vehicle. It is not always possible to fit below the drivers seat in a VW T5.

The final installation location is always decided on the day of install, where our engineer can access your vehicle and proceed with your agreement. All online orders are securely processed by PayPal. This offers our customers an added layer of security and buyer protection. Our standard fitting service is included in the unit price of our fully fitted kits.

Closed Sunday. In all cases the unit is fully warranted against any manufacturing defects with the exception of the glow plug, which is deemed a consumable part. Tearing of the diaphragm is due to dirty fuel. Warranty Policy. Are our heaters manufactured in China? Yes they are along with almost all the electrical goods in your home. Now imagine walking in to the same store without all the products manufactured in China! Are they the same as the ones retailing on Ebay?

No they are not, not that there is actually anything wrong with some of the Ebay units on the market. We order our exclusive units from a recognised manufacturer. We have strict quality requirements and procedures in place to monitor this, our heater units also contain our own software. We also offer an ongoing maintenance contract for subsequent years coverage. The one that seems to be most vocal appears to be 'Planar UK' Funny that, given that only a few years ago they were the ones branded cheap copies of another large brand.

A relevant question to the slayers of chinese product in particular diesel heaters, just where are ALL the components of your heaters manufactured?

Yes they may be assembled in Russia, Germany etc, but that does not include where the component parts were actually made! Why are our heaters so cheap? Yes we do get asked this, but it might be better to ask the others why are your units so expensive! We know our costings, we know our profit levels and as a family run business are happy with that. What shape is yours? Follow the correct table of codes.Menu Menu. Search Everywhere Threads This forum This thread.

Search titles only. Everywhere Threads This forum This thread. Log in Register. Pool School. Support TFP. New posts Conversations Trending Featured Search forums. What's new.

Diesel Air Heater Fault Finding

New threads New posts New media Latest activity. New media Search media. Current visitors. Forum Rules. Thread starter towney Start date Oct 30, JavaScript is disabled. For a better experience, please enable JavaScript in your browser before proceeding. Apr 5, 84 Central Florida. Last time I had this type of issue the thermal regulator was replaced in Pulled the thermistor and tested with a meter and getting 8.

Is there anything else I should test or is this a bad thermistor? Not a pro on multimeter testing so any instruction to narrow the source would be appreciated. Also, when I apply any type heat to thermistor while testing the reading goes down.

chinese diesel heater error codes

Problem: The heater stays on for a bit and then turns off, keeps recycling from on and off.Imported Diesel Heaters fault Codes. Hi Everyone, Cousin has a heater that won't fire up and all it does is flash 4 times in the controller, which I take to be a code for what ever the fault is? Has anyone information on what these codes might be? Are all imported Chinese diesel heaters created equally or as I suspect there are fault codes that vary in there meaning from different manufacturers?

Re: Imported Diesel Heaters fault Codes. Possibly has air in the pipe line to the pump. Disconnect at the pump the line from the tank and get the fuel running thru.

You can carefully, very carefully, turn the key on but not start the vehicle so the fuel runs thru. This won't happen on some set ups but will pump fuel thru the line fast on others. It's very easy to get an air bubble at this join. Then reconnect to the pump and try again. KEA 4 berth model kw 6spd. Hi - Thanks for the replies and suggestions, it gives us something to go on with as they are staying at the moment. Petercw - was it you who said there was a company that did installations and servicing on these imports and was based in Auckland?

Sorry Brian but not me, I did my own install. It's actually quite easy if you take your time. Placement is the hardest thing to decide. I just installed mine last week, and it really was very straightforward. Priming the pump was probably the biggest issue I had, and all it really needed was more time about mins before giving up and restarting which I did about 4 times and presto! Hi Neilv - Yes I installed mine about 2 years ago and it woks fine. My cousin then brought one and installed about a year ago and all worked well.

Then one day a while ago he turned it on and a few seconds later turned it off because he suddenly needed to leave the van. A while prior to this it was started and only went through the start to the point of it igniting, then shut down. This is why I think it is a fuel problem.

He is now registered on this site so should continue the discussion, I'll tell him tomorrow. But I Take your point that to bleed the fuel system does take some time, I think 3 starts before mine fired up. Regards Brian. That gives a better clue to what may have gone wrong.

Options 11 posts 1 2 Next Page 1 of 2 11 posts. Time: 0.Users browsing this forum: Google [Bot] and 1 guest. Imported Diesel Heaters fault Codes. Hi Everyone, Cousin has a heater that won't fire up and all it does is flash 4 times in the controller, which I take to be a code for what ever the fault is? Has anyone information on what these codes might be?

Are all imported Chinese diesel heaters created equally or as I suspect there are fault codes that vary in there meaning from different manufacturers?

Re: Imported Diesel Heaters fault Codes. Possibly has air in the pipe line to the pump.

VVKB Parking Heater Trouble Shooting Guide

Disconnect at the pump the line from the tank and get the fuel running thru. You can carefully, very carefully, turn the key on but not start the vehicle so the fuel runs thru.

This won't happen on some set ups but will pump fuel thru the line fast on others. It's very easy to get an air bubble at this join. Then reconnect to the pump and try again. KEA 4 berth model kw 6spd. Hi - Thanks for the replies and suggestions, it gives us something to go on with as they are staying at the moment.

Petercw - was it you who said there was a company that did installations and servicing on these imports and was based in Auckland? Sorry Brian but not me, I did my own install. It's actually quite easy if you take your time. Placement is the hardest thing to decide.

I just installed mine last week, and it really was very straightforward. Priming the pump was probably the biggest issue I had, and all it really needed was more time about mins before giving up and restarting which I did about 4 times and presto!

Hi Neilv - Yes I installed mine about 2 years ago and it woks fine. My cousin then brought one and installed about a year ago and all worked well. Then one day a while ago he turned it on and a few seconds later turned it off because he suddenly needed to leave the van.

A while prior to this it was started and only went through the start to the point of it igniting, then shut down. This is why I think it is a fuel problem. He is now registered on this site so should continue the discussion, I'll tell him tomorrow.

chinese diesel heater ERROR CODE E-10

But I Take your point that to bleed the fuel system does take some time, I think 3 starts before mine fired up. Regards Brian. That gives a better clue to what may have gone wrong. Options 11 posts 1 2 Next Page 1 of 2 11 posts.

Time: 0.


thoughts on “Chinese diesel heater error codes”